Tel: +86-531-86975099

E-mail: director@pingyungroup.com

PVC Roofing Tile

PingYun 3 layers pvc roofing tile has three layers, top layer is for unti-aging, middle layer is for heat insulation, bottom layer is for unti-fricition. It is widely used for shopping mall, farm house, warehouse, factory and so on.

Send InquiryChat Now
Product Details

PVC roofing tile - W930 style
PingYun W930 is manufactured by 3 layer co-extrusion technology by one time processing it is a ideal material for construction project with anti-corrosion requirements. W930 only has good anti corrosion but also good in heat insulation and soundproof. It is widely used for shopping mall, farm house, warehouse, carport and so on.

image004.jpg


Specifications

Model

W930

Material

ASA+PVC or UPVC

Thickness

1.5mm

2.0mm

2.5mm

3.0mm

Overall width

930mm

Effective width

867mm

Length

Max 5.9m/20FT container; Max11.8m/40HQ container

Purlin distance

800-1000mm

Weight/m2

2.95kg

3.90kg

4.85kg

5.90kg

Quantity/40HQ

9600m2

7200m2

5700m2

4800m2


Profile

1.jpg


Main color

image009.jpg


Excellent advantages

image011.jpg


Why PVC, Not clay, Not steel, Not cement?


PVC

Clay

steel

cement

Color stable

image012.jpg

image015.jpg

image015.jpg

image015.jpg

Lightweight

image012.jpg

image015.jpg

image015.jpg

image015.jpg

Heat insulation

image012.jpg

image012.jpg

image015.jpg

image012.jpg

Anti-corrosion

image012.jpg

image012.jpg

image015.jpg

image012.jpg

Anti-earthquake

image012.jpg

image015.jpg

image012.jpg

image015.jpg


Accessories

image022.jpg


Application
PingYun W930 PVC roofing tile has been widely used in agricultural farm house, industrial chemical plant, factory and warehouse, even shopping mall and villa house.

Installation and notes

1. PINGYUN roofing design requirements
1) Purlin space distance minimum 660mm
2) Roofing pitches 20°- 80°
3) The roofing sheets stands temperature between -30℃to 80℃.
4) There shall not be permanent loads on the roof sheets.

2. Installation of PINGYUN roofing tiles
1) For pitched roof, the roofing sheets at each slope should be installed at the same time with ridge tiles.
2) There should be 30mm gap between roofing sheets and wall for thermal expansion.
3) During installation or maintenance, installers can not walk directly on the roofing sheets, they must
work on safety ladders or supportive purlin, which should cover at least two parallel purlin. It is advised to take any safety measure to make sure the safety of workers.
4) It is not advised to work in a frosty, rainy or snowy weather or wind speed over 10m/s.
5) It is not advised to work under -5℃.
6) It is advised to install by professional or experienced roofer to guarantee the quality of installation.

3. Overlap
1) Every product has a horizontal overlap of one wave.
2) The vertical overlap is one pitch.
3) To avoid the offline of gutter lines, it is advised to cover every second sheet onto the first and third sheet.

4. Fixing
1) All the PINGYUN roofing sheets should be fixed by our supplied special screw set fittings.
2) PINGYUN roof should have at least 4 fittings on every square meter, and the screws must always be at the crest of waves and can not be fastened too tightly or too loosely.
3) For ridge units, horizontal overlaps and eaves, fittings must be fixed at every wave crest.

5. Cutting
PINGYUN roofing sheets should be cut by electrical toothless saw.

6. Drilling holes
1) After positioned properly, the roofing sheets must be electrical drill before fixing.
2) The diameter of drilling holes should be 2mm bigger than that of self-tapping screws(screw is 6mm, hole should be 8mm).
3) Use PVC roofing silicon to make up for holes.


Our Certificate

image027.jpg


Test Report of PVC roofing tile

NO.

Test Item

Test Method

Test Condition

Test Result

1

UV Exposure

ASTM G154-12 ASTM D2244-11

ASTM G154-12 cycle 1, Lamp type:UV340, Exposure period:200h

ΔE*ab=0.5

2

Tensile Strength

ASTM D638-10

Testing speed:50mm/min

26Mpa

3

Flexural Strength

ASTM D790-10 Procedure A

Testing speed:1.3mm/min Span:48mm

52Mpa

4

Impact Resistance

ASTM D5420-10

Geometry GE(Ø12.7mm) Impact Weight:0.9kg

Mean Failure energy:4J

5

High Temperature Resistance


60℃, 6h

No visible change

6

Low Temperature


-35℃, 6h

No visible change

7

Chemical Resistance


70% Ethanol solution(v/v), Immersion test, 23℃, 2h

No visible change

10% NaOH solution Immersion(m/m), test, 23℃, 2h

No visible change

Saturated NaCL solution(m/m), Immersion test, 23℃, 2h

No visible change

8

Thermal Conductivity

ASTM C518-10

Mean Temperature 25.58℃

Temperature difference 9.36℃

Thermal Conductivity 0.071[(W/(M.K)]

9

20mm Vertical burning test

UL94-2013 Section 8

Specimen:129×12.5×3.0mm

V-0

10

Sound Insulation


Compare with metal roof tile

30dB lower

11

Hard to Burn


B1 Grade

Oxygen index 32.4


FAQ:
Q1.
Can I have a sample?
A: Samples are free, but the customer pays for the freight

Q2. What about the lead time?
A: Production starts as soon as payment is received, around 10-15 days..

Q3. Do you offer guarantee for the products?
A: Yes, we offer 30 years warranty to our products.

Q4. Do you have more models?
A: Yes, we have, please check following profiles:

Hot Tags: PVC roofing tile, manufacturers, suppliers, factory, price
Related Products
Inquiry