Tel: +86-531-86975099

E-mail: director@pingyungroup.com

Anti UV Roof Sheet

Plastic roofing (PVC ROOF & ASA ROOF) provide a clean, quick and economical installation with high resistance to fractures, weather.

Send InquiryChat Now
Product Details

anti uv roof sheet
anti uv roof sheet is an excellent waterproof and new multifunctional building material, which are made from PVC and ASA, PVC on bottom is anti-corrosion and no leakage. ASA material on surface is anti-aging and makes color stable.

It's adopted by the most advanced 2 or 3 layer co-extrusion technology for one-time processing. In extreme weather and different climates, it can withstanding winds and earthquakes. It's more reliable and durable than other traditional roofing material, with features of high level of sound absorption and heat insulation, very good load bearing performance, light-weight for easy installation, maintenance and use, which is very suitable for house, villa, tours resort, various types of permanent architectural roof decoration and "flat to slope" project.


Specifications of anti uv roof sheet


Model

R720 R880 R1050

Material

ASA engineering plastic from SABIC, Raw PVC material, and other chemical materials

Thickness

2.3mm

2.5mm

3.0mm

Overall width

720mm 880mm 1050mm

Effective width

640mm 800mm 960mm

Length

Customized, times of 219mm
Max 5.694m for 20FT container, Max11.826m for 40HQ container

Purlin distance

660mm 880mm

Weight/m2

4.6Kgs

5.0Kgs

6.0Kgs

Quantity/40HQ

6000m2

5500m2

4800m2


Profile

1.png



Main color of anti uv roof sheet

image005.jpg


Excellent advantages of anti uv roof sheet

image007.jpg


Accessories of anti uv roof sheet



Application of anti uv roof sheet
1. Super strong weather fastness and long service life
2. Super strong impact resistance, well low temperature resistant effect
3. Excellent anti-loading performance
4. Self-cleaning
5. Thermal insulation and energy saving
6. Color lasting
7. Excellent decay resistance
8. Environment protecting
9. Light mass and easy installation

image013(001).jpg


Installation and notes of anti uv roof sheet
Handling

During handling, the products must not be thrown rudely to avoid damaging or scratching the product surface.

Storage
Store the tiles in dry and flat site with good ventilation. Products should be protected by coverings with good air permeability.

Pitch
Royal Tile is applicable for the pitch from 20°to 80°. For the pitch beyond this range, special measures should be taken during installation.

Purline
1. Anti-corrosion treatment: Metal purlines should be coated with one layer of anti-rust paint and two layers of finishing coatings. Wood purlines should be coated with anti-corrosion or asphalt oil.
2. The top purlines should have 180mm distance from the ridge line in order to install the ridge tiles.
3. The bottom purline should have 50-70mm distance from the eave.
4. The suggested purline spacing is 660mm.


Our Certificate

image015.jpg


Test Report of anti uv roof sheet


NO.

Test Item

Test Method

Test Condition

Test Result

1

UV Exposure

ASTM G154-12 ASTM D2244-11

ASTM G154-12 cycle 1, Lamp type:UV340, Exposure period:200h

ΔE*ab=0.5

2

Tensile Strength

ASTM D638-10

Testing speed:50mm/min

26Mpa

3

Flexural Strength

ASTM D790-10 Procedure A

Testing speed: 1.3mm/min Span:48mm

52Mpa

4

Impact Resistance

ASTM D5420-10

Geometry GE(Ø12.7mm) Impact Weight:0.9kg

Mean Failure energy:4J

5

High Temperature Resistance


60℃, 6h

No visible change

6

Low Temperature


-35℃, 6h

No visible change

7

Chemical Resistance


70% Ethanol solution(v/v), Immersion test, 23℃, 2h

No visible change

10% NaOH solution Immersion(m/m), test, 23℃, 2h

No visible change

Saturated NaCL solution(m/m), Immersion test, 23℃, 2h

No visible change

8

Thermal Conductivity

ASTM C518-10

Mean Temperature 25.58℃

Temperature difference 9.36℃

Thermal Conductivity 0.071[(W/(M.K)]

9

20mm Vertical burning test

UL94-2013 Section 8

Specimen:129×12.5×3.0mm

V-0

10

Sound Insulation


Compare with metal roof tile

30dB lower

11

Hard to Burn


B1 Grade

Oxygen index 32.4



FAQ:
Q: 1, Can you provide different size that we need?
A: Yes, we provide tailor-made products, but the size range of the tiles should smaller than container' s size.

Q: 2, What tools do you use to cut tiles and install screws?
A: Use hand-held portable cutting machines and portable electric drills.

Q: 3, What color of the roof tiles can you provide?
A: Gray, green, white, blue, etc., if you need to customize your color, please offer the samples.

Q: 4, Can you provide samples?
A: Of course, and we provide samples to customers is free, the sample will be ready within four days, but customers need to bear their own freight.

Q: 5, What about delivery date?
A: Within 10 days after advance deposit.

Q: 6, What if I have questions asking for help?
A: We will reply to you within six hours.

Hot Tags: Anti UV Roof Sheet, manufacturers, suppliers, factory, price
Related Products
Inquiry